The best lighting for a wetroom uses IP-rated, waterproof fittings designed specifically for wet environments. LED downlights and recessed ceiling lights are the most popular choices, offering energy efficiency, long lifespan, and clean aesthetics that suit the open, minimal style of a wetroom. The sections below cover everything you need to know, from IP ratings and light types to installation and smart controls.
What IP rating do wetroom lights need to be?
Wetroom lights must carry a minimum IP65 rating in areas directly exposed to water spray, and IP67 or higher for fittings positioned directly over a shower head or in standing water. IP ratings measure how well a fitting resists dust and moisture ingress, and in a wetroom, choosing the correct rating is a safety and compliance requirement, not just a recommendation.
UK wiring regulations (BS 7671) divide bathrooms and wetrooms into lighting zones that determine which IP rating applies where:
- Zone 0: Inside the shower area itself, at floor level or within the shower basin. Only IP67 or IP68 fittings are permitted here.
- Zone 1: The area directly above the shower head, up to 2.25 metres from the floor. IP65 is the minimum requirement.
- Zone 2: The wider bathroom area within 0.6 metres of the shower or bath. IP44 is generally sufficient, though IP65 is recommended for added safety.
- Outside the zones: Standard fittings may be used, though in a fully open wetroom layout, the entire floor area is typically treated as a wet zone.
Because a wetroom has no shower tray or enclosure to contain water, the wet zone effectively extends across the whole room. For this reason, most electricians and specifiers recommend using IP65 or higher fittings throughout the entire wetroom ceiling rather than trying to define precise zone boundaries in an open-plan space.
What types of lights are suitable for a wetroom?
The most suitable lights for a wetroom are recessed LED downlights with an appropriate IP rating, flush ceiling lights, and low-voltage strip lighting used as accent illumination. The key requirement is that every fitting must be rated for wet or damp environments. Surface-mounted standard light fittings are not appropriate for use inside a wetroom.
The most commonly specified options include:
- Recessed IP65 LED downlights: The most popular choice for wetroom ceiling lights. They sit flush with the ceiling, create a clean and uncluttered look, and are widely available in warm, neutral, and cool white colour temperatures.
- Flush IP-rated ceiling lights: A good option where ceiling depth is limited or where a recessed fitting is not practical. These sit flat against the ceiling surface and are straightforward to install.
- LED strip lighting: Useful for accent lighting along shelving, niches, or under a glass screen. Must be IP67 or higher if positioned within Zone 1 or Zone 0.
- Backlit mirrors or vanity lights: Positioned outside the main wet zone, these add functional task lighting for grooming and complement the primary ceiling lights well.
Wall-mounted fittings can also be used in wetrooms, provided they carry the correct IP rating for their position. However, recessed ceiling lights remain the most practical choice because they keep all electrical components out of direct contact with water and steam.
Are LED lights better than halogen in a wetroom?
Yes, LED lights are significantly better than halogen for wetroom use. LEDs run cooler, use far less energy, last much longer, and are available in a wider range of IP-rated fittings suited to wet environments. Halogen bulbs generate considerable heat, which in a steam-filled wetroom can cause fittings to degrade faster and create unnecessary energy waste.
The practical advantages of LED over halogen in a wetroom setting include:
- Energy efficiency: LED fittings typically use around 75 to 80 percent less electricity than equivalent halogen bulbs, which adds up meaningfully over years of daily use.
- Lifespan: A quality LED lamp can last 25,000 hours or more. Halogen bulbs typically last between 1,000 and 2,000 hours, meaning frequent replacement in a frequently used wetroom.
- Heat output: Halogen bulbs become very hot in use. In a sealed, IP-rated fitting, excess heat can shorten the life of the fitting itself. LEDs run cool, reducing this risk.
- Colour temperature range: LEDs are available from warm white (2700K) to cool daylight (6500K), allowing you to match the lighting to the mood and function of the space.
- Dimming compatibility: Many LED fittings are dimmable when paired with a compatible dimmer switch, something halogen could do but which LEDs now match without the associated heat penalty.
Given the availability of IP65 and IP67 LED downlights at accessible price points in 2026, there is little practical reason to specify halogen in a new wetroom installation.
How bright should wetroom lighting be?
A wetroom generally needs between 300 and 500 lumens per square metre for comfortable general lighting. For a small to medium wetroom of around four to six square metres, a total output of 1,500 to 3,000 lumens spread across three to five downlights is a practical starting point. Task areas such as a vanity mirror benefit from additional focused light.
Brightness in a wetroom depends on how the space is used. A wetroom used primarily for showering and daily hygiene routines benefits from bright, even illumination that eliminates shadows and makes the space feel safe and easy to navigate. This is particularly important for older users or those with reduced vision, where poor lighting can increase the risk of slips or falls.
Colour temperature also plays a role in how bright a space feels. A cool white light (around 4000K) feels crisper and more clinical, while warm white (around 2700K to 3000K) creates a more relaxed atmosphere. Many homeowners opt for a neutral white (3000K to 3500K) as a balance between the two, providing good visibility without the harshness of a daylight tone.
If the wetroom is also used as a relaxation space, layering the lighting helps. A brighter main circuit for practical use can be complemented by dimmable accent lighting for a more ambient effect in the evenings.
Can you use smart or dimmable lights in a wetroom?
Yes, you can use smart and dimmable lights in a wetroom, provided the fittings themselves carry the correct IP rating for their zone position. The smart or dimming functionality sits within compatible bulbs, drivers, or control systems rather than the fitting itself, so the waterproofing requirement applies to the luminaire, not the smart feature.
There are a few practical considerations when specifying smart or dimmable wetroom lighting:
- Dimmer compatibility: Not all LED fittings are dimmable. Check that both the LED lamp and the dimmer switch are rated as compatible before purchasing. Using a non-compatible dimmer with an LED can cause flickering or buzzing.
- Smart switches and controls: Smart switches should be positioned outside the wet zones, typically at the door or on a wall well away from the shower area. The smart functionality is controlled remotely or via a hub, so the switch itself does not need to be IP-rated as long as it is outside Zone 2.
- Voice or app control: Smart lighting systems that allow voice or app-based control can be particularly useful in an accessible wetroom, where reaching a light switch may be difficult for some users. This kind of hands-free control adds genuine practical value for people with limited mobility or dexterity.
- Wireless versus wired systems: Both options work in wetrooms. Wireless smart systems are easier to retrofit, while wired systems integrated during the build or renovation offer greater reliability.
Dimmable lighting in a wetroom is a worthwhile investment. The ability to adjust brightness between a bright, functional setting for showering and a softer, ambient level for relaxing makes the space more versatile and comfortable.
Who should install lighting in a wetroom?
Wetroom lighting must be installed by a qualified electrician registered with a competent persons scheme such as NICEIC or NAPIT. In England and Wales, electrical work in a bathroom or wetroom is classified as notifiable work under Part P of the Building Regulations, meaning it must either be carried out by a registered electrician or inspected and certified by the local authority building control department.
This is not a job for DIY installation, regardless of how straightforward the fitting appears. The combination of water, electricity, and the requirement for correct zone compliance makes professional installation essential for safety and legal compliance. An unqualified installation could void home insurance, create a safety hazard, and cause problems when selling the property.
A qualified electrician will:
- Assess the wetroom layout and confirm the lighting zones
- Specify and source fittings with the correct IP rating for each zone
- Install RCD (residual current device) protection on the lighting circuit
- Ensure all wiring and connections are appropriate for a wet environment
- Issue a Part P Building Regulations certificate on completion
When planning a wetroom renovation, it is worth coordinating the lighting design early in the project so that the electrician can work alongside the waterproofing and tiling stages. Recessed downlights in particular need to be positioned before the ceiling is finished, and any structural considerations, such as ceiling depth for the fitting housing, are easier to address before other trades have completed their work.
How Impey Showers supports your wetroom project
While lighting is one element of a successful wetroom, the foundation of any safe and functional space is the waterproofing, drainage, and floor formation system beneath it. Impey Showers provides complete wetroom systems designed to make every installation straightforward, durable, and fully accessible.
- Level-access floor formers with a built-in 1:40 gradient, engineered for timber and concrete floors
- WaterGuard tanking membrane for a guaranteed watertight seal with no drying time required
- Square and linear drainage solutions compatible with all Impey floor formers
- Accessible and assisted-care products including shower seats, grab rails, and half-height shower doors
- Technical support including CAD drawings, on-site surveys, and a national installer training programme
Whether you are adapting a bathroom for accessibility, fitting out a new build, or upgrading an existing shower space, wetroom systems from Impey give you a proven, professionally supported starting point. Contact the Impey team to discuss your project and find the right system for your space.